TESTING STANDARDS

Missile impact refers to the testing procedure where an 8-foot, 9 lb. 2x4 lumber is fired at the door at 50ft/s. This methodology is used for both HVHZ and standard impact testing, it is the pass-fail criteria that differs. STANDARD IMPACT

HVHZ IMPACT To pass HVHZ testing, no air infiltration can pass through the impact area created on the surface of the door after the missile impact. This ensures maximum protection from both wind pressure and flying debris.

To pass standard impact testing, a 3-inch sphere cannot fit through any resulting cracks in the door after the missile impact. This confirms it can resist debris while maintaining structural integrity. Standard Plastpro Opaque Doors * : • Meet standard impact and Wind Borne Debris Region (WBDR) requirements • Can be used in hurricane prone regions outside of Dade and Broward Counties

HVHZ IMPACT

Plastpro HVHZ Impact Doors: • Thicker fiberglass skin • Reinforced internal structure

• Meet HVHZ reqirements and can be used in Dade and Broward Counties

*Opaque door refers to a door without glass

Non-Impact Zones Winds below 140 mph

Wind Borne Debris Regions (WBDR) Regions where the average speed of wind is 140 mph or greater High Velocity Hurricane Zone (HVHZ) HVHZ in Dade and Broward Counties in Florida

TO SEE THE FULL FLORIDA BUILDING CODE APPROVAL DOCUMENT, VISIT WWW.FLORIDABUILDING.ORG THE NOVA 90 FL# IS 28093, 28095 & 29714.